Have you ever seen this video? These guys really screwed up. This was a dangerous and amateurish effort on the part of these firefighters. There are numerous problems that I saw there. Lets review the worst of them.

1 The incident commander apparently failed to recognize that the building was lost. He still had crews operating inside the building during most of the film. Why expose crews to this potential collapse hazard to try and save a building that is already a goner?

2 The building had already self ventilated through the roof, and these guys are still breaking windows. Why?

3 The exposure building on side D (the right) was burning for quite awhile before anyone did anything about it. Have these guys ever heard of exposure control?

4 The ladder that was lying against the building, being exposed to direct flame, was later used as a roof access on the second building. Then the firefighters (and I use the term loosely) compound it by being on the roof without a roof ladder.

The list goes on. In the comments section for the incident, firefighters accuse critics of being “monday morning quarterbacks” and say that if we weren’t there, we cannot criticize. Ridiculous. We kill 100 firefighters a year, and it is time we stop. Lets stop making excuses, and fix this.

Categories: Uncategorized